Ess » Geschiedenis » Versie 8
Micha Kersloot, 12-07-2023 09:35
1 | 1 | Micha Kersloot | h1. Ess |
---|---|---|---|
2 | |||
3 | 4 | Micha Kersloot | {{>toc}} |
4 | |||
5 | 1 | Micha Kersloot | h2. EasySolar II |
6 | |||
7 | h3. Multiplus II |
||
8 | |||
9 | <pre> |
||
10 | TAB: GeneralSystem frequency 50Hz |
||
11 | |||
12 | Shore current 19.0 A |
||
13 | Overruled by remote checked |
||
14 | Dynamic current limiter unchecked |
||
15 | External current sensor connected (see manual) unchecked |
||
16 | State of charge when Bulk finished 95.0 % |
||
17 | Battery capacity 200 Ah |
||
18 | Charge efficiency 0.95 TAB: Grid |
||
19 | Country / grid code standard Germany: VDE-AR-N 4105:2018-11, internal NS protection |
||
20 | |||
21 | AC input 1 Above selected gridcode plus LOM B (compliant) |
||
22 | rise-in-voltage protection U> 253.0 V |
||
23 | start network service HF treshold 50.20 Hz |
||
24 | P(f>) droop 5.00 % |
||
25 | Use Aux1 as disable FeedIn signal checked |
||
26 | Maximum AC current for charge or feed in 100.0 % |
||
27 | Reactive power regulation Use a fixed Cos Phi |
||
28 | Filter time for reactive power 3.3 s |
||
29 | Cos phi at point 1 1.00 TAB: Inverter |
||
30 | PowerAssist unchecked |
||
31 | |||
32 | Inverter output voltage 230 V |
||
33 | Inverter DC shut-down voltage 44.00 V |
||
34 | Inverter DC restart voltage 48.00 V |
||
35 | Low DC alarm level 48.00 V |
||
36 | Do not restart after short-circuit (VDE 2510-2 safety) unchecked |
||
37 | enable AES uncheckedTAB: Charger |
||
38 | Enable charger checked |
||
39 | |||
40 | Weak AC input unchecked |
||
41 | Stop after excessive bulk unchecked |
||
42 | Lithium batteries checked |
||
43 | Disable VSense (for diagnostic purposes) unchecked |
||
44 | Configured for VE.Bus BMS unchecked |
||
45 | Charge curve Fixed |
||
46 | Absorption voltage 52.00 V |
||
47 | Float voltage 51.00 V |
||
48 | Charge current 70 A |
||
49 | Repeated absorption time 1.00 Hr |
||
50 | Repeated absorption interval 7.00 Days |
||
51 | Absorption time 1 HrTAB: Virtual switch |
||
52 | TAB: Usage |
||
53 | Virtual switch usage Do not use VS |
||
54 | TAB: Assistants |
||
55 | TAB: Assistant Configuration |
||
56 | ESS (Energy Storage System) (size:978) |
||
57 | |||
58 | *) System uses LiFePo4 with other type BMS |
||
59 | (This can be either a BMS connected via CAN bus or a BMS system in which the |
||
60 | batteries are protected from high/low cell voltages by external equipment.) |
||
61 | *) The battery capacity of the system is 200 Ah. |
||
62 | *) Sustain voltage 48.00 V. |
||
63 | *) Cut off voltage for a discharge current of: |
||
64 | 0.005 C= 46.00 V |
||
65 | 0.25 C= 46.00 V |
||
66 | 0.7 C= 46.00 V |
||
67 | 2 C= 46.00 V |
||
68 | *) Inverting is allowed again when voltage rises 1.20 V above cut-off(0). |
||
69 | *) Relevant VEConfigure settings: |
||
70 | - Battery capacity 200 Ah. |
||
71 | - PowerAssist unchecked |
||
72 | - Lithium batteries checked |
||
73 | - Dynamic current limiter unchecked |
||
74 | - Storage mode unchecked |
||
75 | |||
76 | |||
77 | Total size of all assistants including the required |
||
78 | (hidden) system assistants is: 1037 |
||
79 | </pre> |
||
80 | 2 | Micha Kersloot | |
81 | h3. GX device |
||
82 | |||
83 | 3 | Micha Kersloot | seems to be an : Allwinner sun8i Family |
84 | 2 | Micha Kersloot | |
85 | https://www.victronenergy.com/live/ccgx:root_access |
||
86 | 5 | Micha Kersloot | |
87 | 6 | Micha Kersloot | *ESPhome grid meter* |
88 | 5 | Micha Kersloot | Using the the following extra software on the GX device to enable mqtt devices to connect to the victron GX and be used as a grid meter: |
89 | 1 | Micha Kersloot | https://github.com/freakent/dbus-mqtt-devices |
90 | |||
91 | 5 | Micha Kersloot | Using the following ESPHome alternate P1 meter configuration to send P1 data to the GX device AND to home assistant: |
92 | |||
93 | 8 | Micha Kersloot | after updating the firmware you seem to need to run the setup.sh script again. |
94 | |||
95 | 1 | Micha Kersloot | [[esphome p1meter victron version]] |
96 | |||
97 | 6 | Micha Kersloot | *GX to Home Assistant* |
98 | |||
99 | To get information from the GX device into home assistant you can use the following HACS addon: https://github.com/sfstar/hass-victron |
||
100 | |||
101 | To get the battery input/output into the energy dashboard you need to split the sensor.victron_system_battery_power into two values with template sensors and add two cummulative entries with the integration platform. |
||
102 | |||
103 | 5 | Micha Kersloot | <pre> |
104 | sensor: |
||
105 | #total battery input energy (cummulate) |
||
106 | - platform: integration |
||
107 | source: sensor.battery_power_input |
||
108 | name: battery_input_energy |
||
109 | unit_prefix: k |
||
110 | method: left |
||
111 | round: 3 |
||
112 | #total battery output energy (cummulate) |
||
113 | - platform: integration |
||
114 | source: sensor.battery_power_output |
||
115 | name: battery_output_energy |
||
116 | unit_prefix: k |
||
117 | method: left |
||
118 | round: 3 |
||
119 | 1 | Micha Kersloot | |
120 | 5 | Micha Kersloot | ---- |
121 | 6 | Micha Kersloot | |
122 | 5 | Micha Kersloot | template: |
123 | - sensor: |
||
124 | - name: "Battery power input" |
||
125 | unique_id: sensor.battery_power_input |
||
126 | device_class: power |
||
127 | unit_of_measurement: "W" |
||
128 | state: > |
||
129 | {% if states('sensor.victron_system_battery_power')|float >= 0 %} |
||
130 | {{ states('sensor.victron_system_battery_power') }} |
||
131 | {% else %} |
||
132 | 0 |
||
133 | {% endif %} |
||
134 | - name: "Battery power output" |
||
135 | unique_id: sensor.battery_power_output |
||
136 | device_class: power |
||
137 | unit_of_measurement: "W" |
||
138 | state: > |
||
139 | {% if states('sensor.victron_system_battery_power')|float < 0 %} |
||
140 | {{ -1 * states('sensor.victron_system_battery_power')|float }} |
||
141 | {% else %} |
||
142 | 0 |
||
143 | {% endif %} |
||
144 | </pre> |
||
145 | 4 | Micha Kersloot | |
146 | 7 | Micha Kersloot | *GX Venus OS Large* |
147 | |||
148 | You can update the firmware with a Venus OS Large version. This version includes Node-RED. In the Remote Console, this can be enabled and you can finde node-red on https://venus:1881/ |
||
149 | 8 | Micha Kersloot | |
150 | when installing Venus OS Large, you better run |
||
151 | |||
152 | /opt/victronenergy/swupdate-scripts/resize2fs.sh |
||
153 | |||
154 | 7 | Micha Kersloot | |
155 | |||
156 | 4 | Micha Kersloot | h2. Pylontech 5000US |