Ess

EasySolar II

Multiplus II

TAB: GeneralSystem frequency    50Hz

Shore current    19.0    A
Overruled by remote    checked
Dynamic current limiter    unchecked
External current sensor connected (see manual)    unchecked
State of charge when Bulk finished    95.0    %
Battery capacity    200    Ah
Charge efficiency    0.95    TAB: Grid
Country / grid code standard    Germany:             VDE-AR-N 4105:2018-11, internal NS protection

AC input 1    Above selected gridcode plus LOM B (compliant)
rise-in-voltage protection U>    253.0    V
start network service HF treshold    50.20    Hz
P(f>) droop    5.00    %
Use Aux1 as disable FeedIn signal    checked
Maximum AC current for charge or feed in    100.0    %
Reactive power regulation    Use a fixed Cos Phi
Filter time for reactive power    3.3    s
Cos phi at point 1    1.00    TAB: Inverter
PowerAssist    unchecked

Inverter output voltage    230    V
Inverter DC shut-down voltage    44.00    V
Inverter DC restart voltage    48.00    V
Low DC alarm level    48.00    V
Do not restart after short-circuit (VDE 2510-2  safety)    unchecked
enable AES    uncheckedTAB: Charger
Enable charger    checked

Weak AC input    unchecked
Stop after excessive bulk    unchecked
Lithium batteries    checked
Disable VSense (for diagnostic purposes)    unchecked
Configured for VE.Bus BMS    unchecked
Charge curve    Fixed
Absorption voltage    52.00    V
Float voltage    51.00    V
Charge current    70    A
Repeated absorption time    1.00    Hr
Repeated absorption interval    7.00    Days
Absorption time    1    HrTAB: Virtual switch
TAB: Usage
Virtual switch usage    Do not use VS
TAB: Assistants
TAB: Assistant Configuration
ESS (Energy Storage System) (size:978)

*)    System uses LiFePo4 with other type BMS
    (This can be either a BMS connected via CAN bus or a BMS system in which the 
    batteries are protected from high/low cell voltages by external equipment.)
*)    The battery capacity of the system is 200 Ah.
*)    Sustain voltage 48.00 V.
*)    Cut off voltage for a discharge current of:
    0.005 C= 46.00 V
    0.25 C= 46.00 V
    0.7 C= 46.00 V
    2 C= 46.00 V
*)    Inverting is allowed again when voltage rises 1.20 V above cut-off(0).
*)    Relevant VEConfigure settings:
      -  Battery capacity 200 Ah.
      -  PowerAssist unchecked
      -  Lithium batteries checked
      -  Dynamic current limiter unchecked
      -  Storage mode unchecked

Total size of all assistants including the required
(hidden) system assistants is: 1037

ongeveer 1 jaar geleden bijgewerkt door Micha Kersloot · 1 revisions