Ess » Geschiedenis » Revisie 2
Revisie 1 (Micha Kersloot, 27-06-2023 13:07) → Revisie 2/16 (Micha Kersloot, 27-06-2023 15:27)
h1. Ess
h2. EasySolar II
h3. Multiplus II
<pre>
TAB: GeneralSystem frequency 50Hz
Shore current 19.0 A
Overruled by remote checked
Dynamic current limiter unchecked
External current sensor connected (see manual) unchecked
State of charge when Bulk finished 95.0 %
Battery capacity 200 Ah
Charge efficiency 0.95 TAB: Grid
Country / grid code standard Germany: VDE-AR-N 4105:2018-11, internal NS protection
AC input 1 Above selected gridcode plus LOM B (compliant)
rise-in-voltage protection U> 253.0 V
start network service HF treshold 50.20 Hz
P(f>) droop 5.00 %
Use Aux1 as disable FeedIn signal checked
Maximum AC current for charge or feed in 100.0 %
Reactive power regulation Use a fixed Cos Phi
Filter time for reactive power 3.3 s
Cos phi at point 1 1.00 TAB: Inverter
PowerAssist unchecked
Inverter output voltage 230 V
Inverter DC shut-down voltage 44.00 V
Inverter DC restart voltage 48.00 V
Low DC alarm level 48.00 V
Do not restart after short-circuit (VDE 2510-2 safety) unchecked
enable AES uncheckedTAB: Charger
Enable charger checked
Weak AC input unchecked
Stop after excessive bulk unchecked
Lithium batteries checked
Disable VSense (for diagnostic purposes) unchecked
Configured for VE.Bus BMS unchecked
Charge curve Fixed
Absorption voltage 52.00 V
Float voltage 51.00 V
Charge current 70 A
Repeated absorption time 1.00 Hr
Repeated absorption interval 7.00 Days
Absorption time 1 HrTAB: Virtual switch
TAB: Usage
Virtual switch usage Do not use VS
TAB: Assistants
TAB: Assistant Configuration
ESS (Energy Storage System) (size:978)
*) System uses LiFePo4 with other type BMS
(This can be either a BMS connected via CAN bus or a BMS system in which the
batteries are protected from high/low cell voltages by external equipment.)
*) The battery capacity of the system is 200 Ah.
*) Sustain voltage 48.00 V.
*) Cut off voltage for a discharge current of:
0.005 C= 46.00 V
0.25 C= 46.00 V
0.7 C= 46.00 V
2 C= 46.00 V
*) Inverting is allowed again when voltage rises 1.20 V above cut-off(0).
*) Relevant VEConfigure settings:
- Battery capacity 200 Ah.
- PowerAssist unchecked
- Lithium batteries checked
- Dynamic current limiter unchecked
- Storage mode unchecked
Total size of all assistants including the required
(hidden) system assistants is: 1037
</pre>
h3. GX device
blijkbaar een Allwinner sun8i Family ingebouwd.
https://www.victronenergy.com/live/ccgx:root_access
https://github.com/freakent/dbus-mqtt-devices
https://github.com/NuKeMtje/ESPHomeDSMRVictron