Ess » Geschiedenis » Versie 2
Micha Kersloot, 27-06-2023 15:27
| 1 | 1 | Micha Kersloot | h1. Ess |
|---|---|---|---|
| 2 | |||
| 3 | h2. EasySolar II |
||
| 4 | |||
| 5 | h3. Multiplus II |
||
| 6 | |||
| 7 | <pre> |
||
| 8 | TAB: GeneralSystem frequency 50Hz |
||
| 9 | |||
| 10 | Shore current 19.0 A |
||
| 11 | Overruled by remote checked |
||
| 12 | Dynamic current limiter unchecked |
||
| 13 | External current sensor connected (see manual) unchecked |
||
| 14 | State of charge when Bulk finished 95.0 % |
||
| 15 | Battery capacity 200 Ah |
||
| 16 | Charge efficiency 0.95 TAB: Grid |
||
| 17 | Country / grid code standard Germany: VDE-AR-N 4105:2018-11, internal NS protection |
||
| 18 | |||
| 19 | AC input 1 Above selected gridcode plus LOM B (compliant) |
||
| 20 | rise-in-voltage protection U> 253.0 V |
||
| 21 | start network service HF treshold 50.20 Hz |
||
| 22 | P(f>) droop 5.00 % |
||
| 23 | Use Aux1 as disable FeedIn signal checked |
||
| 24 | Maximum AC current for charge or feed in 100.0 % |
||
| 25 | Reactive power regulation Use a fixed Cos Phi |
||
| 26 | Filter time for reactive power 3.3 s |
||
| 27 | Cos phi at point 1 1.00 TAB: Inverter |
||
| 28 | PowerAssist unchecked |
||
| 29 | |||
| 30 | Inverter output voltage 230 V |
||
| 31 | Inverter DC shut-down voltage 44.00 V |
||
| 32 | Inverter DC restart voltage 48.00 V |
||
| 33 | Low DC alarm level 48.00 V |
||
| 34 | Do not restart after short-circuit (VDE 2510-2 safety) unchecked |
||
| 35 | enable AES uncheckedTAB: Charger |
||
| 36 | Enable charger checked |
||
| 37 | |||
| 38 | Weak AC input unchecked |
||
| 39 | Stop after excessive bulk unchecked |
||
| 40 | Lithium batteries checked |
||
| 41 | Disable VSense (for diagnostic purposes) unchecked |
||
| 42 | Configured for VE.Bus BMS unchecked |
||
| 43 | Charge curve Fixed |
||
| 44 | Absorption voltage 52.00 V |
||
| 45 | Float voltage 51.00 V |
||
| 46 | Charge current 70 A |
||
| 47 | Repeated absorption time 1.00 Hr |
||
| 48 | Repeated absorption interval 7.00 Days |
||
| 49 | Absorption time 1 HrTAB: Virtual switch |
||
| 50 | TAB: Usage |
||
| 51 | Virtual switch usage Do not use VS |
||
| 52 | TAB: Assistants |
||
| 53 | TAB: Assistant Configuration |
||
| 54 | ESS (Energy Storage System) (size:978) |
||
| 55 | |||
| 56 | *) System uses LiFePo4 with other type BMS |
||
| 57 | (This can be either a BMS connected via CAN bus or a BMS system in which the |
||
| 58 | batteries are protected from high/low cell voltages by external equipment.) |
||
| 59 | *) The battery capacity of the system is 200 Ah. |
||
| 60 | *) Sustain voltage 48.00 V. |
||
| 61 | *) Cut off voltage for a discharge current of: |
||
| 62 | 0.005 C= 46.00 V |
||
| 63 | 0.25 C= 46.00 V |
||
| 64 | 0.7 C= 46.00 V |
||
| 65 | 2 C= 46.00 V |
||
| 66 | *) Inverting is allowed again when voltage rises 1.20 V above cut-off(0). |
||
| 67 | *) Relevant VEConfigure settings: |
||
| 68 | - Battery capacity 200 Ah. |
||
| 69 | - PowerAssist unchecked |
||
| 70 | - Lithium batteries checked |
||
| 71 | - Dynamic current limiter unchecked |
||
| 72 | - Storage mode unchecked |
||
| 73 | |||
| 74 | |||
| 75 | Total size of all assistants including the required |
||
| 76 | (hidden) system assistants is: 1037 |
||
| 77 | </pre> |
||
| 78 | 2 | Micha Kersloot | |
| 79 | h3. GX device |
||
| 80 | |||
| 81 | blijkbaar een Allwinner sun8i Family ingebouwd. |
||
| 82 | |||
| 83 | https://www.victronenergy.com/live/ccgx:root_access |
||
| 84 | https://github.com/freakent/dbus-mqtt-devices |
||
| 85 | https://github.com/NuKeMtje/ESPHomeDSMRVictron |